13 research outputs found

    The Infrared Spectrograph on the Spitzer Space Telescope

    Full text link
    The Infrared Spectrograph (IRS) is one of three science instruments on the Spitzer Space Telescope. The IRS comprises four separate spectrograph modules covering the wavelength range from 5.3 to 38micron with spectral resolutions, R \~90 and 600, and it was optimized to take full advantage of the very low background in the space environment. The IRS is performing at or better than the pre-launch predictions. An autonomous target acquisition capability enables the IRS to locate the mid-infrared centroid of a source, providing the information so that the spacecraft can accurately offset that centroid to a selected slit. This feature is particularly useful when taking spectra of sources with poorly known coordinates. An automated data reduction pipeline has been developed at the Spitzer Science Center.Comment: Accepted in ApJ Sup. Spitzer Special Issue, 6 pages, 4 figure

    Maxadilan Prevents Apoptosis in iPS Cells and Shows No Effects on the Pluripotent State or Karyotype

    Get PDF
    Pituitary adenylate cyclase-activating polypeptide (PACAP) is a structurally endogenous peptide with many biological roles. Maxadilan, a 61-amino acid vasodilatory peptide, specifically activates the PACAP type I receptor (PAC1). Although PAC1 has been identified in embryonic stem cells, little is known about its presence or effects in human induced pluripotent stem (iPS) cells. In the present study, we investigated the expression of PAC1 in human iPS cells by reverse transcriptase polymerase chain reaction (RT-PCR) and western blot analysis. To study the physiological effects mediated by PAC1, we evaluated the role of maxadilan in preventing apoptotic cell death induced by ultraviolet C (UVC). After exposure to UVC, the iPS cells showed a marked reduction in cell viability and a parallel increase of apoptotic cells, as demonstrated by WST-8 analysis, annexin V/propidium iodide (PI) analysis and the terminal transferase dUTP nick end labeling (TUNEL) assay. The addition of 30 nM of maxadilan dramatically increased iPS cell viability and reduced the percentage of apoptotic cells. The anti-apoptotic effects of maxadilan were correlated to the downregulation of caspase-3 and caspase-9. Concomitantly, immunofluorescence, western blot analysis, real-time quantitative polymerase chain reaction (RT-qPCR) analysis and in vitro differentiation results showed that maxadilan did not affect the pluripotent state of iPS cells. Moreover, karyotype analysis showed that maxadilan did not affect the karyotype of iPS cells. In summary, these results demonstrate that PAC1 is present in iPS cells and that maxadilan effectively protects iPS cells against UVC-induced apoptotic cell death while not affecting the pluripotent state or karyotype

    FORCAST: A Mid-Infrared Camera for SOFIA

    No full text
    We describe the Faint Object infraRed CAmera for the SOFIA Telescope (FORCAST) which is presently operating as a facility instrument on the Stratospheric Observatory For Infrared Astronomy (SOFIA). FORCAST provides imaging and moderate resolution spectroscopy capability over the 5-40μm wavelength range. In imaging mode, FORCAST has a 3.4′×3.2′ field-of-view with 0.768′′ pixels. Using grisms, FORCAST provides long-slit low-resolution (R=100-300) and short-slit, cross-dispersed medium-resolution spectroscopic modes (R=800-1200) over select wavelengths. Preceded by both Spitzer and Herschel, the discovery phase space for FORCAST lies in providing unique photometric bands and/or spectroscopic coverage, higher spatial resolution and exploration of the brightest sources which typically saturate space observatories

    Functional morphology of the salivary gland of the snail, Helix pomatia:

    No full text
    Functional morphology of Helix pomatia salivary gland cells was studied at light microscopic level by using different histochemical methods. Three cell types could be demonstrated in the salivary gland: mucocytes, granular and vacuolated cells. The distribution and the number of the different cell types were different in active and inactive snails. In active feeding animals, dilatated interlobular salivary ducts were observed, which were never present in inactive ones. In active animals an additional cell type, the cystic cell could also be observed. Periodic acid Schiff staining revealed both mucuos and serous elements in the salivary gland. Furthermore, hematoxyline-eosin staining indicated the occurrence of a cell layer with high mitotic activity in the acini. Applying immunohistochemical methods with monoclonal mouse anti-human Ki-67 clone, B56 and polyclonal rabbit anti-human Ki-67 antibodies, we also were able to demonstrate the occurrence of dividing cells in the salivary gland. Analysis of 1-2 microm semi-thin Araldite sections stained with toluidine-blue showed that the saliva can be released, in addition to possible exocytosis, by the lysis of cystic cells. Using an apoptosis kit, we could also establish that this process was due to rather an apoptotic than a necrotic mechanism. In the salivary gland of active snails, where an intensive salivation takes place, significantly more apoptotic cells occurred, if compared to that of inactive animals. It is suggested that programmed cell death may also be involved in the saliva release

    Pituitary Adenylate Cyclase Activating Polypeptide (PACAP) and Its Receptors Are Present and Biochemically Active in the Central Nervous System of the Pond Snail Lymnaea stagnalis

    No full text
    PACAP is a highly conserved adenylate cyclase (AC) activating polypeptide, which, along with its receptors (PAC1-R, VPAC1, and VPAC2), is expressed in both vertebrate and invertebrate nervous systems. In vertebrates, PACAP has been shown to be involved in associative learning, but it is not known if it plays a similar role in invertebrates. To prepare the way for a detailed investigation into the possible role of PACAP and its receptors in a suitable invertebrate model of learning and memory, here, we undertook a study of their expression and biochemical role in the central nervous system of the pond snail Lymnaea stagnalis. Lymnaea is one of the best established invertebrate model systems to study the molecular mechanisms of learning and memory, including the role of cyclic AMP-activated signaling mechanisms, which crucially depend on the learning-induced activation of AC. However, there was no information available on the expression of PACAP and its receptors in sensory structures and central ganglia of the Lymnaea nervous system known to be involved in associative learning or whether or not PACAP can actually activate AC in these ganglia. Here, using matrix-assisted laser desorption ionization time of flight (MALDI-TOF) and immunohistochemistry, we established the presence of PACAP-like peptides in the cerebral ganglia and the lip region of Lymnaea. The MALDI-TOF data indicated an identity with mammalian PACAP-27 and the presence of a squid-like PACAP-38 highly homologous to vertebrate PACAP-38. We also showed that PACAP, VIP, and maxadilan stimulated the synthesis of cAMP in Lymnaea cerebral ganglion homogenates and that this effect was blocked by the appropriate general and selective PACAP receptor antagonists

    The Infrared Spectrograph (IRS) on the Spitzer Space Telescope

    No full text
    International audienceThe Infrared Spectrograph (IRS) is one of three science instruments on the Spitzer Space Telescope. The IRS comprises four separate spectrograph modules covering the wavelength range from 5.3 to 38 mum with spectral resolutions, R=lambda/Deltalambda~90 and 600, and it was optimized to take full advantage of the very low background in the space environment. The IRS is performing at or better than the prelaunch predictions. An autonomous target acquisition capability enables the IRS to locate the mid-infrared centroid of a source, providing the information so that the spacecraft can accurately offset that centroid to a selected slit. This feature is particularly useful when taking spectra of sources with poorly known coordinates. An automated data-reduction pipeline has been developed at the Spitzer Science Center

    The Infrared Spectrograph (IRS) on the Spitzer Space Telescope

    No full text
    International audienceThe Infrared Spectrograph (IRS) is one of three science instruments on the Spitzer Space Telescope. The IRS comprises four separate spectrograph modules covering the wavelength range from 5.3 to 38 mum with spectral resolutions, R=lambda/Deltalambda~90 and 600, and it was optimized to take full advantage of the very low background in the space environment. The IRS is performing at or better than the prelaunch predictions. An autonomous target acquisition capability enables the IRS to locate the mid-infrared centroid of a source, providing the information so that the spacecraft can accurately offset that centroid to a selected slit. This feature is particularly useful when taking spectra of sources with poorly known coordinates. An automated data-reduction pipeline has been developed at the Spitzer Science Center
    corecore